Comparison of two portable solid state detectors with an improved collimation and alignment device for mammographic x-ray spectroscopy

2006

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detecto…

Materials sciencebusiness.industryDetectorX-ray detectorGeneral MedicineCadmium telluride photovoltaicsCollimated lightCadmium zinc telluridechemistry.chemical_compoundOpticschemistryIonization chamberPinhole (optics)businessHalf-value layerMedical Physics
researchProduct

X-ray spectroscopy and dosimetry with a portable CdTe device.

2007

Abstract X-ray spectra and dosimetry information are very important for quality assurance (QA) and quality control (QC) in medical diagnostic X-ray systems. An accurate knowledge of the diagnostic X-ray spectra would improve the patient dose optimization, without compromising image information. In this work, we performed direct diagnostic X-ray spectra measurements with a portable device, based on a CdTe solid-state detector. The portable device is able to directly measure X-ray spectra at high photon fluence rates, as typical of clinical radiography. We investigated on the spectral performances of the system in the mammographic energy range (up to ∼40 keV). Good system response to monoener…

PhysicsX-ray spectroscopy CdTe detectorsNuclear and High Energy Physicsmedicine.medical_specialtyReproducibilitybusiness.industryDetectorExposure HVLFluenceFull width at half maximumQuality (physics)OpticsmedicineDosimetryMedical physicsSpectroscopybusinessInstrumentationHalf-value layer
researchProduct

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

2010

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…

Physicsbusiness.industryDetectorX-ray detectorGeneral MedicinePhoton countingFull width at half maximumOpticsQuality (physics)Ionization chamberSpectroscopybusinessNuclear medicineHalf-value layerMedical Physics
researchProduct

Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System

2012

In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate X-ray spectroscopy in mammography (1–30 keV). The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole…

digital pulse processingmammographyAnalytical chemistrylcsh:Chemical technologyBiochemistryArticleAnalytical ChemistryCdTe detectorsCdTe detectorOpticsmedicineCadmium CompoundsMammographylcsh:TP1-1185Computer SimulationElectrical and Electronic EngineeringInstrumentationPhysicsDosimetermedicine.diagnostic_testbusiness.industryAttenuationSpectrum AnalysisX-RaysDetectorSettore FIS/01 - Fisica Sperimentalehigh photon counting rateCdTe detectors Digital Pulse Processing MammographySignal Processing Computer-AssistedAtomic and Molecular Physics and OpticsPhoton countingSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Full width at half maximumX-ray spectroscopy; high photon counting rate; CdTe detectors; digital pulse processing; mammographyIonization chamberX-ray spectroscopyTelluriumbusinessHalf-value layerSensors; Volume 12; Issue 6; Pages: 8390-8404
researchProduct

Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

2008

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calc…

medicine.medical_specialtyMaterials sciencePhotonbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineRadiationComputational physicsElectromagnetic shieldingmedicineMedical physicsRadiation protectionbusinessHalf-value layerBeam (structure)Medical Physics
researchProduct

Broad-beam transmission data for new brachytherapy sources, Tm-170 and Yb-169

2005

The characteristics of the radionuclides (170)Tm and (169)Yb are highly interesting for their use as high dose-rate brachytherapy sources. The introduction of brachytherapy equipment containing these sources will lead to smaller required thicknesses of the materials used in radiation protection barriers compared with the use of conventional sources such as (192)Ir and (137)Cs. The purpose of this study is to determine the required thicknesses of protection material for the design of the protecting walls. Using the Monte Carlo method, transmission data were derived for broad-beam geometries through lead and concrete barriers, from which the first half value layer and tenth value layer are ob…

medicine.medical_specialtyMaterials sciencemedicine.medical_treatmentBrachytherapyBrachytherapyMonte Carlo methodOpticsmedicineHumansRadiology Nuclear Medicine and imagingMedical physicsYtterbiumRadioisotopesRadiationRadiological and Ultrasound Technologybusiness.industryPublic Health Environmental and Occupational HealthRadiotherapy DosageGeneral MedicineBeam transmissionIridium RadioisotopesTransmission (telecommunications)Cesium RadioisotopesThuliumCalibrationDose reductionRadiation protectionbusinessMonte Carlo MethodHalf-value layerRadiation Protection Dosimetry
researchProduct